Home ProductsProtein Purification System

High Precision Protein Purification System 2mL / 5mL Dynamic Mixer For Gene Therapy Drug

Good quality Ion Exchange Chromatography Resin for sales
I'm Online Chat Now

High Precision Protein Purification System 2mL / 5mL Dynamic Mixer For Gene Therapy Drug

China High Precision Protein Purification System 2mL / 5mL Dynamic Mixer For Gene Therapy Drug supplier

Large Image :  High Precision Protein Purification System 2mL / 5mL Dynamic Mixer For Gene Therapy Drug

Product Details:

Place of Origin: China
Brand Name: SCG
Certification: Yes
Model Number: SCG-030/100/300

Payment & Shipping Terms:

Minimum Order Quantity: Negotiable
Price: Negotiable
Packaging Details: 1 main unit
Delivery Time: In one week after payment
Payment Terms: L/C, T/T
Supply Ability: No limitation
Contact Now
Detailed Product Description
Flow Rate Precision And Accuracy: ±1.2%、 0.5%RSD Dynamic Mixer: 2mL/2mL/5mL
Maximum Pressure: 4000psi(27MPa)/1500psi(10MPa) /1000psi(6.8Mpa) Wavelength Accuracy: ±1nm、±0.5nm

Characteristic

Main featuresof the SCG protein purification system include:

 

· The key components of the system arejointly developed, and produced by industrial well-known highly-respected manufacturersin the United States and Europe, which establishes a foundation for topquality, superior performance and high reliability;

· All parts in contact with samples are madeof bio-inert materials such as peek, sapphire, ruby,etc., makes the system compatible with protein and other biological samples, and is resistantto strong acid, alkali, high salt etc.

· The system has good stability and excellentinfusion precision at low temperature and low pressure.

· The US imported fluid delivery systemcontains two dual piston binary gradient pump, providing high accuracy andprecision liquid delivery. It isequipped with automatic self-cleaning function to avoid damaging and polluting the pumphead from salt and other substances precipitation.

· The UV detector is an imported DAD detectorenabling the simultaneous monitor of multiple wavelength signals, as well asfull arrange scanning. and make real-time monitor the purity of separationcomponents easily.

· The system also provides real-timemonitoring of pH/ conductivity. An on-line measure of temperatures compensatefor pH and conductivity as required to achieve more accurate monitoring.

· The new fractioncollector which accommodates a wide variety of collecting tubes/containers to facilitatecollecting the target fractions.

· All valves (such as Auto-sampleinjecting valve, Column selectingvalves, sample collecting valve, Multi-buffer selecting valve, column valve,etc.) are customized for our need by the international well-known manufacturers.The users can choose the appropriate valve according to their experiments.

ordering information

Module SCG-030 SCG-100 SCG-300
SCG Dual piston pump Imported low pressure PEEK pump, bio-inert material, can provide a continuous stable and accurate flow rate

Flow rate range

Maximum pressure

Dynamic mixer

Flow rate Precision and accuracy

Gradient type

0.001-36 mL/min 0.01-100ml/min 0.1-300ml/min

4000psi(27MPa) 1500psi(10MPa) 1000psi(6.8Mpa)

2ml 2 mL 5mL

±1.2%, 0.5%RSD

 

Linear, Equal Degree and Step Gradient. Gradient ratio can be modified online.

DAD 400EX UV-detector wavelength range:200-400nm, Simultaneous detection of two wavelengths. Using imported deuterium lamp as light source. An external flow cell and 2 mm optical path length.
Wavelength accuracy and repeatability drift and noise

±1nm,±0.5nm

1×10-3 AU/Hr,±4×10-5 AU(1s)

Sample injection valve Auto-injection. Software controls the switch of the functions of Load, Inject and Waste. Supporting for the sample quantitative ring and the quantitative cup injection.
Conductivity detector Range: 0.001-999.99mS/cm. Accuracy: ± 2%. The detection cell volume: 20ul
Temperature sensor Range: 0-100 ℃. Accuracy: ±1 ℃. Temperature compensation can be carried out on the conductivity and pH.
Chromatography workstation SCG Chromatography workstation
(Including the workstation software, brand computers and genuine Win7 operating system)
kit SCG start package
(Including PEEK/PTFE pipe, installation manuals, user manuals, pipe joints, common tools, etc.)
pH detector(Recommend) Range : 0-14. Accuracy : ±0.1
Solvent tray(Recommend) Solvent placement is more convenient and save space


UV-detector

DF1 Single wavelength detector 280nm,monitor 1 wavelength, 2mm path length

DF2EX UV-detector 280&260nm, simultaneousmonitoring the 2 wavelength, 2mm path length

DAD 600EX UV-detector 200-600nm, simultaneous monitoring 4wavelengths, 2mm path length

DAD 800EX UV-detector 190-840nm, simultaneous monitoring 4wavelengths, 2mm path length

Ultraviolet flow cell standard configuration: 2mm,optional: 5mm or 10mm path length

 

System pump inlet

A pump inlet 1 (standard), 2 * (A1/A2), 6, 10

B pump inlet 1 (standard), 2 * (B1/B2), 6, 10

Bubble sensor When bubbles are detected, thesystem will be suspended or go into the next method.

* SCG300 does not support two inlets

 

Collection module

Collection valve Two channels, large volumecollection valve (1 waste liquid, 1

outlet)

Six channels, largevolume collection valve (1 waste liquid, 5

outlets)

Ten channels, largevolume collection valve (1 waste liquid, 9

outlets)

Collector type SCG FC-S2, compact size, twoof the same or different collection shelfs can be placed.

Collectionrack type 13mmcollection rack, can be placed 5ml centrifuge tubes (90/rack)

16mmcollection rack, can be placed 15ml centrifuge tubes (60/rack)

28mmcollection rack, can be placed 50ml centrifuge tubes (21/rack)

Deep well plate collection rack, can be placed96-wells microplates (up to 4plates total)

Column support Independentcolumn supporting shelf, suitable for ID: 6.6-50mm diameter of the column and1ml or 5ml preloaded column

Wifi module Wireless monitoring. Suitable forAndroid mobile phone or tablet

Contact Details
YELI BIOTECH (SHANGHAI) CO., LTD

Contact Person: sheng

Send your inquiry directly to us (0 / 3000)